<svg xmlns="http://www.w3.org/2000/svg" viewBox="0 0 760 470" font-family="Segoe UI,Helvetica,Arial,sans-serif"><rect x="0" y="0" width="760" height="470" rx="14" fill="#0d1117"/><text x="20" y="30" fill="#e6edf3" font-size="19" font-weight="700">3D IC: go vertical — bond two wafers, or build the second tier in place</text><text x="20" y="50" fill="#8b949e" font-size="12.5">Parallel 3D bonds finished wafers via TSV or Cu-Cu; monolithic 3D grows a new transistor tier on top, in place</text><!-- ===== PANEL 1 ===== --><rect x="20" y="66" width="226" height="298" rx="7" fill="#0c141d" stroke="#30363d"/><text x="36" y="92" fill="#38bdf8" font-size="14" font-weight="700">1 · Two ways to go vertical</text><!-- LEFT: parallel bond --><text x="83" y="110" text-anchor="middle" fill="#9fd8ef" font-size="10.5" font-weight="700">Parallel — bond</text><rect x="44" y="124" width="78" height="20" rx="2" fill="#233041" stroke="#6f8fb0"/><text x="83" y="138" text-anchor="middle" fill="#adb5bd" font-size="9">die 2</text><line x1="44" y1="145" x2="122" y2="145" stroke="#38bdf8" stroke-width="1" stroke-dasharray="3 2"/><rect x="44" y="146" width="78" height="20" rx="2" fill="#1c2733" stroke="#6f8fb0"/><text x="83" y="160" text-anchor="middle" fill="#adb5bd" font-size="9">die 1</text><rect x="48" y="168" width="70" height="9" fill="#3a2c1e" stroke="#5a4632"/><g stroke="#b8732e" stroke-width="1.6"><line x1="60" y1="124" x2="60" y2="177"/><line x1="90" y1="124" x2="90" y2="177"/><line x1="108" y1="124" x2="108" y2="177"/></g><text x="83" y="190" text-anchor="middle" fill="#c98a2e" font-size="8">TSV / Cu-Cu bond</text><!-- RIGHT: monolithic --><text x="186" y="110" text-anchor="middle" fill="#7ee6c0" font-size="10.5" font-weight="700">Monolithic — in place</text><rect x="150" y="124" width="72" height="16" rx="2" fill="#16332a" stroke="#3f9d6f"/><text x="186" y="136" text-anchor="middle" fill="#adb5bd" font-size="8.5">tier 2</text><rect x="150" y="150" width="72" height="16" rx="2" fill="#1c2733" stroke="#3f9d6f"/><text x="186" y="162" text-anchor="middle" fill="#adb5bd" font-size="8.5">tier 1</text><rect x="154" y="168" width="64" height="9" fill="#3a2c1e" stroke="#5a4632"/><g stroke="#7ee6c0" stroke-width="0.9"><line x1="158" y1="140" x2="158" y2="150"/><line x1="166" y1="140" x2="166" y2="150"/><line x1="174" y1="140" x2="174" y2="150"/><line x1="182" y1="140" x2="182" y2="150"/><line x1="190" y1="140" x2="190" y2="150"/><line x1="198" y1="140" x2="198" y2="150"/><line x1="206" y1="140" x2="206" y2="150"/><line x1="214" y1="140" x2="214" y2="150"/></g><text x="186" y="190" text-anchor="middle" fill="#7ee6c0" font-size="8">inter-tier via (nm)</text><text x="36" y="214" fill="#adb5bd" font-size="11">Parallel bonds two finished</text><text x="36" y="229" fill="#adb5bd" font-size="11">wafers; monolithic grows tier 2</text><text x="36" y="254" fill="#7ee6c0" font-size="11" font-weight="700">directly on tier 1 — no bond.</text><text x="36" y="279" fill="#8b949e" font-size="10.5">Inter-tier vias are far denser</text><text x="36" y="293" fill="#8b949e" font-size="10.5">than any bonded connection —</text><text x="36" y="307" fill="#8b949e" font-size="10.5">that is the whole point.</text><!-- ===== PANEL 2 ===== --><rect x="267" y="66" width="226" height="298" rx="7" fill="#0c141d" stroke="#30363d"/><text x="283" y="92" fill="#38bdf8" font-size="14" font-weight="700">2 · Vertical pitch ladder</text><text x="283" y="120" fill="#c9d1d9" font-size="10.5">microbump</text><text x="474" y="120" text-anchor="end" fill="#e0913a" font-size="9.5">~30–40 µm</text><g fill="#b8732e"><circle cx="288" cy="130" r="1.9"/><circle cx="310" cy="130" r="1.9"/><circle cx="332" cy="130" r="1.9"/><circle cx="354" cy="130" r="1.9"/><circle cx="376" cy="130" r="1.9"/><circle cx="398" cy="130" r="1.9"/></g><text x="283" y="160" fill="#c9d1d9" font-size="10.5">TSV</text><text x="474" y="160" text-anchor="end" fill="#e0b13a" font-size="9.5">~5–10 µm</text><g fill="#b8732e"><circle cx="288" cy="170" r="1.9"/><circle cx="301" cy="170" r="1.9"/><circle cx="314" cy="170" r="1.9"/><circle cx="327" cy="170" r="1.9"/><circle cx="340" cy="170" r="1.9"/><circle cx="353" cy="170" r="1.9"/><circle cx="366" cy="170" r="1.9"/><circle cx="379" cy="170" r="1.9"/><circle cx="392" cy="170" r="1.9"/></g><text x="283" y="200" fill="#c9d1d9" font-size="10.5">Cu-Cu hybrid bond</text><text x="474" y="200" text-anchor="end" fill="#7ee6c0" font-size="9.5">< 1 µm</text><g fill="#7ee6c0"><circle cx="288" cy="210" r="1.7"/><circle cx="295" cy="210" r="1.7"/><circle cx="302" cy="210" r="1.7"/><circle cx="309" cy="210" r="1.7"/><circle cx="316" cy="210" r="1.7"/><circle cx="323" cy="210" r="1.7"/><circle cx="330" cy="210" r="1.7"/><circle cx="337" cy="210" r="1.7"/><circle cx="344" cy="210" r="1.7"/><circle cx="351" cy="210" r="1.7"/><circle cx="358" cy="210" r="1.7"/><circle cx="365" cy="210" r="1.7"/><circle cx="372" cy="210" r="1.7"/><circle cx="379" cy="210" r="1.7"/><circle cx="386" cy="210" r="1.7"/><circle cx="393" cy="210" r="1.7"/></g><text x="283" y="240" fill="#c9d1d9" font-size="10.5">monolithic inter-tier via</text><text x="474" y="240" text-anchor="end" fill="#a99cf0" font-size="9.5">~50–100 nm</text><g fill="#a99cf0"><circle cx="287" cy="250" r="1.4"/><circle cx="291" cy="250" r="1.4"/><circle cx="295" cy="250" r="1.4"/><circle cx="299" cy="250" r="1.4"/><circle cx="303" cy="250" r="1.4"/><circle cx="307" cy="250" r="1.4"/><circle cx="311" cy="250" r="1.4"/><circle cx="315" cy="250" r="1.4"/><circle cx="319" cy="250" r="1.4"/><circle cx="323" cy="250" r="1.4"/><circle cx="327" cy="250" r="1.4"/><circle cx="331" cy="250" r="1.4"/><circle cx="335" cy="250" r="1.4"/><circle cx="339" cy="250" r="1.4"/><circle cx="343" cy="250" r="1.4"/><circle cx="347" cy="250" r="1.4"/><circle cx="351" cy="250" r="1.4"/><circle cx="355" cy="250" r="1.4"/><circle cx="359" cy="250" r="1.4"/><circle cx="363" cy="250" r="1.4"/></g><line x1="283" y1="266" x2="477" y2="266" stroke="#30363d"/><text x="283" y="286" fill="#adb5bd" font-size="10.5">Finer vertical pitch = finer 3D</text><text x="283" y="301" fill="#adb5bd" font-size="10.5">partitioning: whole chips, then</text><text x="283" y="316" fill="#adb5bd" font-size="10.5">blocks, then individual gates.</text><text x="283" y="341" fill="#8b949e" font-size="10">Bonding buys density; monolithic</text><text x="283" y="354" fill="#8b949e" font-size="10">buys another 100x on top.</text><!-- ===== PANEL 3 ===== --><rect x="514" y="66" width="226" height="298" rx="7" fill="#0c141d" stroke="#30363d"/><text x="530" y="92" fill="#38bdf8" font-size="14" font-weight="700">3 · Thermal budget & payoffs</text><text x="530" y="112" fill="#34d399" font-size="11.5" font-weight="700">Payoffs</text><g fill="#34d399"><circle cx="534" cy="125" r="2.6"/><circle cx="534" cy="140" r="2.6"/><circle cx="534" cy="155" r="2.6"/><circle cx="534" cy="170" r="2.6"/></g><text x="544" y="128" fill="#c9d1d9" font-size="10.5">Shorter global wires</text><text x="544" y="143" fill="#c9d1d9" font-size="10.5">Memory directly over logic</text><text x="544" y="158" fill="#c9d1d9" font-size="10.5">CFET: nFET over pFET, tiny cells</text><text x="544" y="173" fill="#c9d1d9" font-size="10.5">New floorplans across tiers</text><line x1="530" y1="185" x2="724" y2="185" stroke="#30363d"/><text x="530" y="205" fill="#e0b13a" font-size="11.5" font-weight="700">The thermal wall</text><g fill="#e0b13a"><circle cx="534" cy="218" r="2.6"/><circle cx="534" cy="233" r="2.6"/><circle cx="534" cy="248" r="2.6"/><circle cx="534" cy="263" r="2.6"/></g><text x="544" y="221" fill="#adb5bd" font-size="10.5">Tier-2 built cold (<~500 °C) so</text><text x="544" y="234" fill="#adb5bd" font-size="10.5">tier-1 devices survive</text><text x="544" y="251" fill="#adb5bd" font-size="10.5">Buried tiers are hard to cool</text><text x="544" y="266" fill="#adb5bd" font-size="10.5">Yield multiplies across tiers</text><text x="530" y="292" fill="#f87171" font-size="10.5" font-weight="700">Heat removal and low-temp device</text><text x="530" y="306" fill="#f87171" font-size="10.5" font-weight="700">quality are the real limits.</text><!-- ===== BOTTOM CARDS ===== --><rect x="20" y="384" width="226" height="70" rx="7" fill="#111a24" stroke="#30363d"/><text x="36" y="406" fill="#38bdf8" font-size="12.5" font-weight="700">Bond or build-in-place</text><text x="36" y="424" fill="#adb5bd" font-size="10">Stack and bond two finished wafers,</text><text x="36" y="437" fill="#adb5bd" font-size="10">or grow a second transistor tier</text><text x="36" y="450" fill="#adb5bd" font-size="10">sequentially on the first.</text><rect x="267" y="384" width="226" height="70" rx="7" fill="#111a24" stroke="#30363d"/><text x="283" y="406" fill="#a99cf0" font-size="12.5" font-weight="700">Density sets the payoff</text><text x="283" y="424" fill="#adb5bd" font-size="10">From TSV µm to monolithic-via nm,</text><text x="283" y="437" fill="#adb5bd" font-size="10">finer vertical pitch moves you from</text><text x="283" y="450" fill="#adb5bd" font-size="10">chip-level to gate-level 3D.</text><rect x="514" y="384" width="226" height="70" rx="7" fill="#111a24" stroke="#30363d"/><text x="530" y="406" fill="#e0b13a" font-size="12.5" font-weight="700">Heat & thermal budget bite</text><text x="530" y="424" fill="#adb5bd" font-size="10">Buried tiers are hard to cool, and</text><text x="530" y="437" fill="#adb5bd" font-size="10">monolithic's top tier must be built</text><text x="530" y="450" fill="#adb5bd" font-size="10">cold enough to spare the bottom.</text></svg>
Monolithic 3D VLSI Integration is stacking multiple device layers on silicon via sequential processing for extreme integration density — achieves 3-4x density gain. Monolithic 3D transcends 2D planar limits. Sequential Processing grow first layer, insulate, pattern vias, repeat for next layer. Layer-by-layer construction enables vertical integration. Thermal Budget second layer processing limited by first layer (interconnects stable to ~500°C for copper). Requires lower-temperature processes for upper layers. Channel Material Quality regrown silicon via solid-phase crystallization or transfer maintains crystallinity. Device Stacking stack transistors vertically. Significant footprint reduction. Interlayer Connections vias through dielectric connect layers. Contact/via resistance critical. 3D Density theoretical 3x improvement; practical 2-2.5x accounting for overhead. Prototype Status demonstrated by MIT, Samsung on research circuits. Not yet production volume. Power Efficiency shorter interconnects reduce capacitance, power dissipation. Thermal Management lower tiers' heat dissipates through upper layers, challenging. Stress Control CTE mismatch between materials; engineering mitigates via films. Gate Engineering gate-last compatible with sequential processing. Yield Challenges first-tier defects propagate; yield lower than 2D. Monolithic 3D achieves maximum density through stacked sequential processing.
Explore 500+ Semiconductor & AI Topics
From EUV lithography to CUDA optimization — search the full knowledge base or chat with our AI assistant.