Chip Foundry Services Request Assessment

Ion Implantation Dose Measurement

Dose Measurement and Control: Step 5 — Precise Ion Counting and Integration

As the ion beam scans across the wafer, the total number of dopant ions reaching the wafer surface must be precisely measured and controlled. Step 5 implements dose monitoring — $\text{real-time}$ measurement of ion current and integration to determine total dose $(ions/cm^2). The$ dose is one of the most critical parameters in ion implantation because dopant concentration in the wafer directly determines electrical properties. Too little dose produces insufficient dopant concentration; too much produces dopant precipitation or defects. Step 5 maintains dose uniformity across the wafer to within $\pm 2–3\%$, ensuring every device receives the correct dopant concentration.

1. Faraday Cup and Current Integration

dose = (total charge $collected)/(wafer$ area × elementary charge) $= \dfrac{Q}{A \cdot e}$

A Faraday cup — a metal electrode in the ion beam path — collects ions and measures the induced current. The current (in amperes) is the number of charges per second; integrating this current over implantation time gives total charge. Dividing by elementary charge (e = 1.6×10⁻¹⁹ C) gives total number of ions. Dividing by wafer area gives dose in $ions/cm^2. Modern$ implanters use real-time dose feedback — the measured dose is compared continuously to target, and if the dose rate is drifting (due to source instability or $\text{beam-steering}$ drift), the scanning parameters are adjusted to maintain constant dose accumulation.

2. Real Diagram: Dose Integration and Feedback Control

Dose Control: Integration and Feedback I(t) → ∫I dt → Q → dose = Q/(A·e); feedback maintains target dose implantation time → I (µA) beam current Faraday cup I meter implantation time → dose (ions/cm²) target if dose drifts low → increase dwell time / decrease scan speed Typical Dose Targets Emitter implant (BJT): 5×10¹⁵ As⁺/cm² @ 100 keV Base implant: 1×10¹⁴ B⁺/cm² @ 50 keV Well implant (CMOS): 1×10¹² P⁺/cm² @ 500 keV precise dose control ensures correct dopant concentration; feedback maintains uniformity

3. Dose Uniformity and Wafer-to-Wafer Repeatability

The dose must be uniform across the wafer (within $\pm 2–3\%$) and repeatable from wafer to wafer (wafer-to-wafer variation <5%). This requires stable beam current, accurate dose integration, and feedback control. Some implanters use beam normalization — the ion source current is continuously monitored and regulated to stay constant, independent of temperature or gas pressure variations.

4. Dose Offset and Correction

Wafer holders and shadowing can cause some areas to receive slightly less ion flux. Step 5 includes dose correction algorithms — the scanning pattern is adjusted to deliver slightly higher dose to regions that naturally receive less, ensuring uniform final dose across the wafer.

5. Real Diagram: Faraday Cup and Current Integration

Dose Measurement and Control Faraday Cup and Current Integration, Dose Uniformity and Wafer-to-Waf… Faraday Cup and Cur…1Dose Uniformity and…2Dose Offset and Cor…3 sequence progression outcome trend (schematic) companion diagram: stage sequence and schematic trend for this step

Dose Measurement's Place in the Process Lineage

Dose measurement and control is step 5 of the ion implantation series — ensuring the correct total number of dopant ions reaches the wafer. Step 6 covers wafer handling and temperature management. Steps 7–8 continue through $\text{post-implant}$ processing. Steps 9–25 cover implantation physics and annealing.