Ion Implantation Dose Measurement

# Dose Measurement and Control: Step 5 — Precise Ion Counting and Integration

As the ion beam scans across the wafer, the total number of dopant ions reaching the wafer surface must be precisely measured and controlled. Step 5 implements dose monitoring — real-time measurement of ion current and integration to determine total dose (ions/cm²). The dose is one of the most critical parameters in ion implantation because dopant concentration in the wafer directly determines electrical properties. Too little dose produces insufficient dopant concentration; too much produces dopant precipitation or defects. Step 5 maintains dose uniformity across the wafer to within ±2–3%, ensuring every device receives the correct dopant concentration.

## 1. Faraday Cup and Current Integration

$$\text{dose} = \frac{\text{total charge collected}}{\text{wafer area} \times \text{elementary charge}} = \frac{Q}{A \cdot e}$$

A Faraday cup — a metal electrode in the ion beam path — collects ions and measures the induced current. The current (in amperes) is the number of charges per second; integrating this current over implantation time gives total charge. Dividing by elementary charge (e = 1.6×10⁻¹⁹ C) gives total number of ions. Dividing by wafer area gives dose in ions/cm². Modern implanters use real-time dose feedback — the measured dose is compared continuously to target, and if the dose rate is drifting (due to source instability or beam-steering drift), the scanning parameters are adjusted to maintain constant dose accumulation.

## 2. Real Diagram: Dose Integration and Feedback Control

Dose Control: Integration and Feedback I(t) → ∫I dt → Q → dose = Q/(A·e); feedback maintains target dose implantation time → I (µA) beam current Faraday cup I meter implantation time → dose (ions/cm²) target if dose drifts low → increase dwell time / decrease scan speed Typical Dose Targets Emitter implant (BJT): 5×10¹⁵ As⁺/cm² @ 100 keV Base implant: 1×10¹⁴ B⁺/cm² @ 50 keV Well implant (CMOS): 1×10¹² P⁺/cm² @ 500 keV precise dose control ensures correct dopant concentration; feedback maintains uniformity

## 3. Dose Uniformity and Wafer-to-Wafer Repeatability

The dose must be uniform across the wafer (within ±2–3%) and repeatable from wafer to wafer (wafer-to-wafer variation <5%). This requires stable beam current, accurate dose integration, and feedback control. Some implanters use beam normalization — the ion source current is continuously monitored and regulated to stay constant, independent of temperature or gas pressure variations.

## 4. Dose Offset and Correction

Wafer holders and shadowing can cause some areas to receive slightly less ion flux. Step 5 includes dose correction algorithms — the scanning pattern is adjusted to deliver slightly higher dose to regions that naturally receive less, ensuring uniform final dose across the wafer.

## 5. Real Diagram: Faraday Cup and Current Integration

Dose Measurement and Control Faraday Cup and Current Integration, Dose Uniformity and Wafer-to-Waf… Faraday Cup and Cur…1Dose Uniformity and…2Dose Offset and Cor…3 sequence progression outcome trend (schematic) companion diagram: stage sequence and schematic trend for this step

## Dose Measurement's Place in the Process Lineage

Dose measurement and control is step 5 of the ion implantation series — ensuring the correct total number of dopant ions reaches the wafer. Step 6 covers wafer handling and temperature management. Steps 7–8 continue through post-implant processing. Steps 9–25 cover implantation physics and annealing.