Semi E130.1
SEMI E130.1 defines the exact SECS-II message set for PSEM300 — the specific status-variable IDs (SVIDs) for chuck position and wafer-map progress, remote-command definitions for load/align/step/unload sequencing, and collection-event IDs (CEIDs) for probe-step completion and end-of-wafer events — rather than the general prober model E130 establishes. E130 says a 300 mm prober should expose a consistent wafer-handling geometry, coordinate reference frame, and load-align-step-unload sequence; E130.1 is the protocol-binding companion that fixes precisely which SECS-II messages, remote commands, and variable numbers carry that exchange, the same relationship nearly every SEMI equipment model has to its own ".1" binding — now applied to wafer probers instead of process tools.
The reason E130 needed its own protocol-binding companion is the same gap every equipment-model specialization closes the same way: a defined geometry and sequencing behavior in prose still leaves the actual remote-command structure and SVID/CEID numbering open to each prober vendor's own implementation, so two E130-compliant probers can step across a wafer map using different commands and variable IDs the host has to reconcile by hand. E130.1 removes that gap by fixing the SECS-II message set itself, so a fab's host software can write one GEM driver against E130.1's defined numbering scheme and have it work against any vendor's 300 mm prober, rather than maintaining a per-vendor mapping table for driving load/align/step/unload cycles and tracking chuck position.
E130.1 completes PSEM300 the same way every ".1" protocol binding completes its base standard: E130 defines what a 300 mm prober and its host have to exchange, and E130.1 is the fixed SECS-II numbering scheme that makes that exchange identical across prober vendors, so a fab's host software never has to special-case a prober by brand to get usable chuck-position and wafer-map-progress data out of it.